spotread(1)


READ

READ

NAME
DESCRIPTION

NAME

Read − Read Print Spot values.

DESCRIPTION

Read Print Spot values, Version 1.3.5 Author: Graeme W. Gill, licensed under the GPL Version 2 or later usage: spotread [−options] [logfile]

−v

Verbose mode

−s

Print spectrum for each reading

−S

Plot spectrum for each reading

−c listno

Set communication port from the following list (default 1)

1 = ’/dev/ttyS0’ 2 = ’/dev/ttyS1’ 3 = ’/dev/ttyS2’ 4 = ’/dev/ttyS3’

−t

Use transmission measurement mode

−d

Use display measurement mode (absolute results)

−db

Use display white brightness relative measurement mode

−dw

Use display white relative measurement mode

−p

Use projector measurement mode (absolute results)

−pb

Use projector white brightness relative measurement mode

−pw

Use projector white relative measurement mode

−e

Use emissive measurement mode (absolute results)

−a

Use ambient measurement mode (absolute results)

−f

Use ambient flash measurement mode (absolute results)

−y c|l

Display type (if emissive), c = CRT, l = LCD

−i illum

Choose illuminant for print/transparency spectral data: A, C, D50 (def.), D65, F5, F8, F10 or file.sp

−o observ

Choose CIE Observer for spectral data or CCSS instrument: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 (Choose FWA during operation)

−F filter

Set filter configuration (if aplicable):

n

None

p

Polarising filter

6

D65

u

U.V. Cut

−E extrafilterfile

Apply extra filter compensation file

−x

Display Yxy instead of Lab

−h

Display LCh instead of Lab

−T

Display correlated color temperatures and CRI

−N

Disable auto calibration of instrument

−H

Start in high resolution spectrum mode (if available)

−X file.ccmx

Apply Colorimeter Correction Matrix

−X file.ccss

Use Colorimeter Calibration Spectral Samples for calibration

−W n|h|x

Override serial port flow control: n = none, h = HW, x = Xon/Xoff

−D [level]

Print debug diagnostics to stderr

logfile

Optional file to save reading results as text

Author: Graeme W. Gill, licensed under the GPL Version 2 or later usage: spotread [−options] [logfile]

−v

Verbose mode

−s

Print spectrum for each reading

−S

Plot spectrum for each reading

−c listno

Set communication port from the following list (default 1)

1 = ’/dev/ttyS0’ 2 = ’/dev/ttyS1’ 3 = ’/dev/ttyS2’ 4 = ’/dev/ttyS3’

−t

Use transmission measurement mode

−d

Use display measurement mode (absolute results)

−db

Use display white brightness relative measurement mode

−dw

Use display white relative measurement mode

−p

Use projector measurement mode (absolute results)

−pb

Use projector white brightness relative measurement mode

−pw

Use projector white relative measurement mode

−e

Use emissive measurement mode (absolute results)

−a

Use ambient measurement mode (absolute results)

−f

Use ambient flash measurement mode (absolute results)

−y c|l

Display type (if emissive), c = CRT, l = LCD

−i illum

Choose illuminant for print/transparency spectral data: A, C, D50 (def.), D65, F5, F8, F10 or file.sp

−o observ

Choose CIE Observer for spectral data or CCSS instrument: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 (Choose FWA during operation)

−F filter

Set filter configuration (if aplicable):

n

None

p

Polarising filter

6

D65

u

U.V. Cut

−E extrafilterfile

Apply extra filter compensation file

−x

Display Yxy instead of Lab

−h

Display LCh instead of Lab

−T

Display correlated color temperatures and CRI

−N

Disable auto calibration of instrument

−H

Start in high resolution spectrum mode (if available)

−X file.ccmx

Apply Colorimeter Correction Matrix

−X file.ccss

Use Colorimeter Calibration Spectral Samples for calibration

−W n|h|x

Override serial port flow control: n = none, h = HW, x = Xon/Xoff

−D [level]

Print debug diagnostics to stderr

logfile

Optional file to save reading results as text



spotread(1)