Calibrate a Display, Version 1.3.5 Author: Graeme W. Gill, licensed under the AGPL Version 3 Diagnostic: Usage requested usage: dispcal [options] outfile
−v [n] |
Verbose mode |
−display displayname Choose X11 display name
−d n[,m]
Choose the display n from the following list (default 1) Optionally choose different display m for VideoLUT access
XRandR 1.2 is faulty − falling back to older extensions
1 = ’Hitachi/HINT W240D DVI at 0, 0, width 1920, height 1200’ 2 = ’ProView/EMC/PTS at 0, 0, width 1280, height 1024’
−c listno
Set communication port from the following list (default 1)
1 = ’/dev/ttyS0’ 2 = ’/dev/ttyS1’ 3 = ’/dev/ttyS2’ 4 = ’/dev/ttyS3’
−r |
Report on the calibrated display then exit |
|||
−R |
Report on the uncalibrated display then exit |
|||
−m |
Skip adjustment of the monitor controls |
−o [profile.icc]
Create fast matrix/shaper profile [different filename to outfile.icc]
−O "description"
Fast ICC Profile Description string (Default "outfile")
−u |
Update previous calibration and (if −o used) ICC profile VideoLUTs |
−q [lmh]
Quality − Low, Medium (def), High
−p |
Use projector mode (if available) |
|||
−y c|l |
Display type, c = CRT, l = LCD |
−t [temp]
White Daylight locus target, optional target temperaturee in deg. K (deflt.)
−T [temp]
White Black Body locus target, optional target temperaturee in deg. K
−w x,y |
Set the target white point as chromaticity coordinates |
−b bright
Set the target white brightness in cd/m^2
−g gamma
Set the target response curve advertised gamma (Def. 2.4) Use "−gl" for L*a*b* curve Use "−gs" for sRGB curve Use "−g709" for REC 709 curve (should use −a as well!) Use "−g240" for SMPTE 240M curve (should use −a as well!)
−G gamma
Set the target response curve actual technical gamma
−f [degree]
Amount of black level accounted for with output offset (default all output offset)
−a ambient
Use viewing condition adjustment for ambient in Lux
−k factor
Amount to try and correct black point hue. Default 1.0, LCD default 0.0
−A rate
Rate of blending from neutral to black point. Default 4.0
−B blkbright
Set the target black brightness in cd/m^2
−e [n] |
Run n verify passes on final curves | ||
−E |
Run only verify pass on installed calibration curves |
−P ho,vo,ss
Position test window and scale it ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc. ss: 0.5 = half, 1.0 = normal, 2.0 = double etc.
−F |
Fill whole screen with black background | ||
−K |
Don’t use VideoLUT to set high precision test values | ||
−n |
Don’t set override redirect on test window | ||
−J |
Run instrument calibration first (used rarely) | ||
−N |
Disable auto calibration of instrument | ||
−H |
Use high resolution spectrum mode (if available) | ||
−V |
Use adaptive measurement mode (if available) |
−X file.ccmx
Apply Colorimeter Correction Matrix
−X file.ccss
Use Colorimeter Calibration Spectral Samples for calibration
−Q observ
Choose CIE Observer for spectrometer or CCSS colorimeter data: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c
−I b|w |
Drift compensation, Black: −Ib, White: −Iw, Both: −Ibw |
−C "command"
Invoke shell "command" each time a color is set
−M "command"
Invoke shell "command" each time a color is measured
−W n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
−D [level]
Print debug diagnostics to stderr
inoutfile
Base name for created or updated .cal and .icc output files
Author: Graeme W. Gill, licensed under the AGPL Version 3 Diagnostic: Usage requested usage: dispcal [options] outfile
−v [n] |
Verbose mode |
−display displayname Choose X11 display name
−d n[,m]
Choose the display n from the following list (default 1) Optionally choose different display m for VideoLUT access
XRandR 1.2 is faulty − falling back to older extensions
1 = ’Hitachi/HINT W240D DVI at 0, 0, width 1920, height 1200’ 2 = ’ProView/EMC/PTS at 0, 0, width 1280, height 1024’
−c listno
Set communication port from the following list (default 1)
1 = ’/dev/ttyS0’ 2 = ’/dev/ttyS1’ 3 = ’/dev/ttyS2’ 4 = ’/dev/ttyS3’
−r |
Report on the calibrated display then exit |
|||
−R |
Report on the uncalibrated display then exit |
|||
−m |
Skip adjustment of the monitor controls |
−o [profile.icc]
Create fast matrix/shaper profile [different filename to outfile.icc]
−O "description"
Fast ICC Profile Description string (Default "outfile")
−u |
Update previous calibration and (if −o used) ICC profile VideoLUTs |
−q [lmh]
Quality − Low, Medium (def), High
−p |
Use projector mode (if available) |
|||
−y c|l |
Display type, c = CRT, l = LCD |
−t [temp]
White Daylight locus target, optional target temperaturee in deg. K (deflt.)
−T [temp]
White Black Body locus target, optional target temperaturee in deg. K
−w x,y |
Set the target white point as chromaticity coordinates |
−b bright
Set the target white brightness in cd/m^2
−g gamma
Set the target response curve advertised gamma (Def. 2.4) Use "−gl" for L*a*b* curve Use "−gs" for sRGB curve Use "−g709" for REC 709 curve (should use −a as well!) Use "−g240" for SMPTE 240M curve (should use −a as well!)
−G gamma
Set the target response curve actual technical gamma
−f [degree]
Amount of black level accounted for with output offset (default all output offset)
−a ambient
Use viewing condition adjustment for ambient in Lux
−k factor
Amount to try and correct black point hue. Default 1.0, LCD default 0.0
−A rate
Rate of blending from neutral to black point. Default 4.0
−B blkbright
Set the target black brightness in cd/m^2
−e [n] |
Run n verify passes on final curves | ||
−E |
Run only verify pass on installed calibration curves |
−P ho,vo,ss
Position test window and scale it ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc. ss: 0.5 = half, 1.0 = normal, 2.0 = double etc.
−F |
Fill whole screen with black background | ||
−K |
Don’t use VideoLUT to set high precision test values | ||
−n |
Don’t set override redirect on test window | ||
−J |
Run instrument calibration first (used rarely) | ||
−N |
Disable auto calibration of instrument | ||
−H |
Use high resolution spectrum mode (if available) | ||
−V |
Use adaptive measurement mode (if available) |
−X file.ccmx
Apply Colorimeter Correction Matrix
−X file.ccss
Use Colorimeter Calibration Spectral Samples for calibration
−Q observ
Choose CIE Observer for spectrometer or CCSS colorimeter data: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c
−I b|w |
Drift compensation, Black: −Ib, White: −Iw, Both: −Ibw |
−C "command"
Invoke shell "command" each time a color is set
−M "command"
Invoke shell "command" each time a color is measured
−W n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
−D [level]
Print debug diagnostics to stderr
inoutfile
Base name for created or updated .cal and .icc output files
![]() |