Read − Read Target Test Chart.
Read Target Test Chart, Version 1.3.5 Author: Graeme W. Gill, licensed under the AGPL Version 3 usage: chartread [−options] outfile
−v |
Verbose mode |
−c listno
Set communication port from the following list (default 1)
1 = ’/dev/ttyS0’ 2 = ’/dev/ttyS1’ 3 = ’/dev/ttyS2’ 4 = ’/dev/ttyS3’
−t |
Use transmission measurement mode | ||
−d |
Use display measurement mode (white Y relative results) | ||
−y c|l |
Display type (if emissive), c = CRT, l = LCD | ||
−e |
Emissive for transparency on a light box | ||
−p |
Measure patch by patch rather than strip |
−x [lx]
Take external values, either L*a*b* (−xl) or XYZ (−xx).
−n |
Don’t save spectral information (default saves spectral) | ||
−l |
Save CIE as D50 L*a*b* rather than XYZ | ||
−L |
Save CIE as D50 L*a*b* as well as XYZ | ||
−r |
Resume reading partly read chart |
−I file.cal
Override calibration info from .ti2 in resulting .ti3
−F filter
Set filter configuration (if aplicable):
n |
None |
|||
p |
Polarising filter |
|||
6 |
D65 |
|||
u |
U.V. Cut |
|||
−N |
Disable auto calibration of instrument |
|||
−B |
Disable auto bi−directional strip recognition |
|||
−H |
Use high resolution spectrum mode (if available) |
−T ratio
Modify strip patch consistency tolerance by ratio
−S |
Suppress wrong strip & unexpected value warnings |
−W n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
−D [level]
Print debug diagnostics to stderr
outfile
Base name for input[ti2]/output[ti3] file
Author: Graeme W. Gill, licensed under the AGPL Version 3 usage: chartread [−options] outfile
−v |
Verbose mode |
−c listno
Set communication port from the following list (default 1)
1 = ’/dev/ttyS0’ 2 = ’/dev/ttyS1’ 3 = ’/dev/ttyS2’ 4 = ’/dev/ttyS3’
−t |
Use transmission measurement mode | ||
−d |
Use display measurement mode (white Y relative results) | ||
−y c|l |
Display type (if emissive), c = CRT, l = LCD | ||
−e |
Emissive for transparency on a light box | ||
−p |
Measure patch by patch rather than strip |
−x [lx]
Take external values, either L*a*b* (−xl) or XYZ (−xx).
−n |
Don’t save spectral information (default saves spectral) | ||
−l |
Save CIE as D50 L*a*b* rather than XYZ | ||
−L |
Save CIE as D50 L*a*b* as well as XYZ | ||
−r |
Resume reading partly read chart |
−I file.cal
Override calibration info from .ti2 in resulting .ti3
−F filter
Set filter configuration (if aplicable):
n |
None |
|||
p |
Polarising filter |
|||
6 |
D65 |
|||
u |
U.V. Cut |
|||
−N |
Disable auto calibration of instrument |
|||
−B |
Disable auto bi−directional strip recognition |
|||
−H |
Use high resolution spectrum mode (if available) |
−T ratio
Modify strip patch consistency tolerance by ratio
−S |
Suppress wrong strip & unexpected value warnings |
−W n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
−D [level]
Print debug diagnostics to stderr
outfile
Base name for input[ti2]/output[ti3] file
![]() |